LK Manifold RF is made of stainless steel, the variants having 1 to 12 floor heating circuits. The manifold is delivered pre-mounted in brackets. The manifold has thermometers on the supply and return, manual air-bleed valves and filling/drain valves*.(*Manifold RF 1 is supplied without thermometer or filling/drain valve)The upper manifold marked FLOW (supply) is fitted with flow indicators graded from 0,5-5 l/min and adjustment valves for the adjustment of individual circuit flows. The flow indicators are made of temperature and impact resistant plastic. The plastic is resistant to anti-freeze, as well as glycol and ethanol with up to 50% respective 30% mix. The lower manifold marked RETURN has hand actuators for shutting off individual circuits. The hand actuators are normally replaced with LK Actuator. Primary flow and return can be connected from the left or right-hand sides. The manifold is ready to be connected to the left-hand side on delivery. Connection from the right is done by removing the end cap assemblies. Connection dimension 1" female thread.Marking plates for identifying individual floor heating circuits, assembly instructions and a protective bag used to protect the manifold from e.g. splashes of concrete during the assembly period are enclosed. The manifold requires additionally:Two LK Ball Valves (Art. no. 241 75 50) or LK Ball Valve Angle (Art. no. 241 79 58). Where appropriate, the ball valve is replaced by LK OptiFlow EVO II. See product range for LK Adjustment Valves. LK Connection Coupling for pipe range dim: PE-X/PAL pipe in dim 16 (Art. no. 241 72 98) / PE-X pipe in dim 12x2 (Art. no. 241 94 66 ) / PE-X pipe in dim 20x2 (Art. no. 241 94 68). Alternatively:LK Press Connection for pipe dim: PE-X/PAL pipe in dim 16 (Art. no. 187 66 06)/PE-X in dim 20x2 (Art. no. 241 94 70).LK Connection Couplings for PE-X pipe 8x1, PE-X/PAL pipe 20x2,8 and copper pipe 12x1,0 and 15x1,0 are available as accessories. Connection dimensions:Connection feed pipe, 1" female Connection under floor heating pipe, ¾" male Eurocone Dimensions:The dimensions of the manifold are listed in the table below. Center dimension pipe connections is 50 mm with 25 mm displacement between flow and return. Additional length for accessories are stated below.LK Ball Valve Straight: 65 mm LK Ball Valve Angle: 70 mm LK By-Pass RF: 15 mm LK By-Pass Delta P RF: 155 mm LK OptiFlow EVO II incl joint nipple straight: 123 mm LK OptiFlow EVO II incl joint nipple elbow: 93 mm
LK Connection Coupling RF
LK Connection Coupling RF 17x2,0
LK Connection Coupling RF CU
LK Adapter
LK PushFit 8, Single female thread
LK PushFit 8, Duo
LK PushFit 8, Quattro
LK Press Connection RF
LK Manifold Screw Plug
LK By-Pass RF
LK By-Pass Delta P RF
LK Automatic Air Vent RF
LK Connection VKF RF/1-Circuit Valve Set
LK Ball Valve straight 1"
LK Ball Valve angle 1"
LK OptiFlow EVO II
LK Connection Set straight
LK Connection Set angle
LK Joint Nipple
LK Valve kit VKF RF
LK Adjustment valve supply, Manifold RF
LK Cap adjustment valve, Manifold RF
LK Glass to flow indicator 0,5-5 l/min, Manifold RF
LK Key set flow indicator, Manifold RF
LK Adapter LK 26, Manifold RF
LK Return valve complete, VKF RF
LK Return valve, VKF RF (bulk packaging)
LK Return valve handle, Manifold RF
LK Marking plate R
LK Thermometer 0 - 80ºC
LK End reducer, Manifold RF
LK Plug ½"
LK Drain valve, Manifold RF
LK EuroConus nipple, Manifold RF
LK Bracket pair, Manifold RF
LK Air vent ½"
Our website uses cookies
We use cookies to ensure that we give you the best user experience on our website. By using our website you accept our use of cookies.
Find out more about cookies